8-ID
  8-ID Beamline logbook mirror  Not logged in ELOG logo
Message ID: 833     Entry time: Fri Mar 11 18:11:36 2022
Author: Eric Dufresne 
Type: 8-ID General 
Category: Beamline Hardware 
Subject: COS for 8-ID says the cylinder is empty at about 150 psi 
From: Strzalka, Joe <[email protected]>
Sent: Friday, March 11, 2022 10:07 AM
To: Zhang, Xiaoyi <[email protected]>; DYS_General <[email protected]>;
[email protected] <[email protected]>; Ziegler, Raymond <[email protected]>
Cc: Kastengren, Alan L. <[email protected]>
Subject: RE: Note on helium usage within DYS and TRR - UPDATE

Hi All,

Seems like the COS for 8-ID says the cylinder is empty at about 150 psi, and then draws on
the other cylinder. Does anyone know -- is there a way to lower that setpoint, maybe to 50 psi?

Joe

Re: Note on helium usage within DYS and TRR - UPDATE
Ziegler, Raymond <[email protected]>
Fri 3/11/2022 11:41 AM
To: Strzalka, Joe <[email protected]>; Zhang, Xiaoyi <[email protected]>;
DYS_General <[email protected]>; [email protected] <[email protected]>
Cc: Kastengren, Alan L. <[email protected]>

Good point Joe. I think I had looked into that quite a while ago but came up empty. I'll review my notes
and follow up again. A great idea considering the current circumstances... As a last resort, if you leave
the one low cylinder in place, the COS will eventually use up all possible helium from both cylinders.
Something to consider before swapping a "not so empty" cylinder...

Thanks,
Ray
ELOG V3.1.4-395e101