Message ID: 850     Entry time: Mon Jul 4 14:53:34 2022
Author: Eric Dufresne 
Type: 8-ID-I 
Category: Beamline Hardware 
Subject: 8ID-I/E shutter problem linked to digital IO  
See problem report: https://logbook.xray.aps.anl.gov/8id/controls/138

Suresh wrote me this on 7/4/2022:
"Found shutter problem with digital IO as well in 8idi fixed using softglue instead
Will do the same for you tomorrow as well
That digital io closes after opening momentarily and that is why macro wasn't working
Use showbeam and block beam or sb and bb in spec, fast shutter open/close buttons won't
work but the status is still valid"

On 7/5/2022 Suresh implemented this softglue turn around (see att 1.).
Attachment 1: 4521_001.pdf  150 kB  Uploaded Tue Jul 5 14:54:26 2022