8-ID
  8-ID Beamline logbook mirror  Not logged in ELOG logo
Message ID: 561     Entry time: Tue Jan 16 16:37:23 2018
Author: Joe Strzalka 
Type: 8-ID-"G" 
Category: Sample Environments 
Subject: Linkam HFSX350-GI Stage for thermal annealing -- Part 3 
Part 3 of information about the Linkam HFSX350-GI Stage for thermal annealing, continues from
Part 1: entry 540/mirror 540
Part 2: entry 560/mirror 560

Drawings of the adapter plates for mounting Linkam into Nealey GIXS chamber, designed by Mike Fisher
Secure adapter with M5 x 14 mm screws
Mount Linkam to adapter with M3 x 10 mm screws

Attachment 1: 3-D rendering of Linkam stage mounted in chamber
Attachment 2: Assembly drawing of the adapter
Attachment 3: Bottom plate
Attachment 4: Legs
Attachment 5: Top plate
Attachment 1: 8-ID-I_GISAXS_WITH_LINKAM_STAGE_UPDATED_12-11-17.pdf  345 kB
Attachment 2: GISX-325.pdf  338 kB
Attachment 3: GISX-326.pdf  220 kB
Attachment 4: GISX-327.pdf  188 kB
Attachment 5: GISX-328.pdf  217 kB
ELOG V3.1.4-395e101