Entry  Fri Feb 17 15:23:13 2006, Alec, 8-ID General, Detectors, PI Direct Detection CCD slowCCD.gifPI_fast.gifPI_eff.gifslowCCD.ps
Some data on the MIT direct detection CCD in use at IMM-CAT

CCD type: 
Pixel Array: 1152X1242
Pixel Size: 22.5 microns square
Full well capacity:

Digitizer: 12 bit/1 Mhz 430khz/16bit  
Serial No: 
Absorption Efficiency: Approximately 40% at 7.66 keV
Photon spread: 
Si Conversion ratio: 3.65
eV/photon pair;
Distance from Be window to CCD chip .543 inches

ADU Gain: approximately 223 electrons/ADU (slow) and 38.4  fast
( had been 330 adu/phot
Entry  Thu Feb 16 13:53:12 2006, Alec, 8-ID-I, Setups, 8-ID-I distances 
Distances along 8ID-I beamline: COSAXS

Item                            Distance from Source (mm) Distance to Sample (mm)
Entry  Wed Feb 15 15:39:16 2006, Alec, Other, Setups, Legacy TRXS lineup document trxs-table.ps
Beginnings of a startup procedures for peridot and mica.

1) login as user1 to topaz
Entry  Wed Feb 15 15:37:54 2006, Alec, 8-ID-E, Setups, Legacy TRXS description document 
TRXS setup:

The vertical spectrometer consists on a 2 circle diffractometer Huber 420.
Entry  Wed Feb 15 15:25:37 2006, Alec, Other, Controls, Legacy table potentiometer information 
Legacy table potentiometer information from the 8-ID web site:

How do I use the potentiometers on the t2 table in the A hutch
Entry  Wed Feb 15 13:32:36 2006, Alec, 8-ID General, EPS, EPS Trip 
[B]What to do on an EPS trip[/B]

The main (manual) EPS control and display panel is located between the E and I stations
Entry  Wed Feb 15 13:17:54 2006, Alec, 8-ID-E, Procedures, Legacy Zone plate set-up information from old web site 
Legacy Zone plate set-up information from old web site:

Entry  Wed Feb 15 13:15:04 2006, Alec, 8-ID General, Controls, X-Ray info (from old web site) 
X-Ray eye info from old web site - not sure of validity:

******* X-RAY EYE *******
Entry  Wed Feb 15 12:09:28 2006, Alec, 8-ID General, Setups, 8-ID Energy and Undulator Gap 
8-ID's nominal operating energy, except via prior consultation with the 8-ID beamline staff, is 7.45 keV (Undulator Gap=17.60 mm)---our current best estimate
is the actual peak energy delivered by the undulator is 100 eV lower than this or 7.35 keV.
Entry  Wed Feb 15 12:02:39 2006, Alec, 8-ID General, Procedures, Aligning mirror after a fill 
The procedure to align E and I stations after a beam fill is:

[LIST]
Entry  Wed Feb 15 11:56:17 2006, Alec, 8-ID General, Controls, How to start EPICS (medm really) 
How to start EPICS or more properly start display the medm display manager:

Enter 'start_epics' (without the single quotes) from one of the 8-ID control computers
Entry  Tue Feb 14 10:58:59 2006, Alec, 8-ID-D, Setups, 8-ID-D monochromator positions 
Undulator Gap = 17.7 mm
Energy (1st Harmonic) = 7.5 keV
Entry  Tue Feb 14 10:05:02 2006, Larry, 8-ID General, Other, Discussion of choosing best photon energy for COSAXS ChoosingEnergy.pdf
 
Entry  Tue Feb 14 09:42:32 2006, Alec, 8-ID-D, Beamline Hardware, 8-ID-D Monochromator Venting and Pumpdown Procedure Mono_valve2.jpg
[B]Diamond Monochromator
pump down & venting procedure[/B]
Entry  Tue Feb 14 09:18:03 2006, Alec, 8-ID General, Computers and Network, List of devices on the 8-ID network 
A list of devices on the 8-ID network (or assigned to the network), can be obtained by entering
'ypcat hosts | grep 116' at a command prompt on a Linux workstation/desktop
Entry  Tue Feb 14 09:15:23 2006, Alec, 8-ID General, Computers and Network, 8-ID Experiment Floor Computer Jack Layout JackLayout_20040920.pptJackLayout_20040920.png
8-ID Experiment Floor Computer Jack Layout.  There should be a one-to-one correspondance to the ports on the experiment floor switch.
Entry  Wed Feb 8 11:05:09 2006, Alec, 8-ID General, Detectors, MCA and Multi-element detector set-up info from the X26 at the NSLS 
MCA and Multi-element detector set-up info from the X26 at the NSLS:
http://www.bnl.gov/x26a/comp_med.shtml
Entry  Tue Feb 7 13:37:46 2006, Alec, 8-ID-D, Hardware, Monochromator ion pump operation Mono_ionp_ctr.jpg
[I][B]Diamond Monochormator ion pump operation instructions[/B][/I]

On the controller, ion pump #1 is the larger pump attached to the vacuum chamber and ion pump #2 is the smaller pump hooked-up to the intermediate stage
Entry  Mon Feb 6 17:24:05 2006, Xuefa, 8-ID-E, Setups, Si(220) beam position on the Entrance Be window 
I estimated the minimum distance from the diamond crystal to the top side of the exit flansch to 675 mm, assuming the following bragg angles at 7.4keV (100eV
removed from actual Undulator settings), Si(111)  31.0 deg and Si(220)  51.8 deg and using the separation of the two burn spots measured by Xuefa. This
means, that the distance crystal to the Si(111) exit port is 740 mm and the distance crystal to the Si(220) exit port is 676 mm.  
Entry  Mon Feb 6 16:26:02 2006, Alec, 8-ID General, EPS, Legacy EPS wiring plc_wiring.asc
Legacy (pre switchover to ASD-SI in 2004) wiring diagram for the EPS.  Also, does not include the slave IOC's added to 8-ID-E and 8-ID-I.